Fulton’s feedwater/condensate return systems are designed to facilitate the safe and efficient storage and pumping of condensate as well as make-up water back to your boiler. These critical systems help increase the safety, reliability, and the useful life of your system.
By offering a comprehensive solution for storing make-up water and return condensate, Fulton’s feedwater and condensate return systems help eliminate the need for expensive additional equipment.
ATI of New York is the authorized manufacturer’s representative for Fulton. Our team boasts decades of experience and will work to carefully understand your needs. Once we understand your application and facility needs, we’ll guide you toward the best feedwater and condensate return system.
We regularly suggest one of the two Fulton feedwater and condensate return systems:
- Horizontal feedwater and condensate return systems
- Vertical Feedwater and condensate return systems
Continue reading to learn more about some of the key highlights of each system.
Fulton Horizontal Feedwater and Condensate Return System
Fulton condensate return systems are assembled with the equipment you’ll need to accommodate your boiler. These systems are engineered for boilers ranging from 4 HP up to 500 HP. A standard horizontal feedwater and condensate return system includes:
- Shut-off valve
- Tank
- High pressure pump
- Stand
- Gauge glass assembly
- Overflow and drain openings
Key Highlights
All Fulton systems are manufactured with the highest quality materials to ensure a long life. A few of the key highlights of the horizontal condensate return system are:
- Rigid welded support frame for enhanced durability and longevity;
- Heavy-gauge, properly sized tank created for fast installation, simple removal, and efficient replacement;
- Heavy-duty feed water pump with the functionality to perform under demanding conditions.
These systems also offer optional preheat kits. The standard pump is functional for a maximum water temperature of 180°F. You can request a special pump for a higher temperature.
Fulton Horizontal Feedwater Models & Dimensions
The Fulton horizontal feedwater/condensate return system is offered in a range of models to accommodate a range of boilers and needs:
- Model HT10 is designed for boilers ranging from 4-12.5 HP with a capacity to hold up to 33 gallons
- Model HT20 is designed for boilers ranging from 13-21 HP with a capacity to hold up to 40 gallons
- Model HT30 is designed for boilers ranging from 22-30 HP with a capacity to hold up to 46 gallons
- Model HT50 is designed for boilers ranging from 31-50 HP with a capacity to hold up to 71 gallons
- Model HT60 is designed for boilers ranging from 51-60 HP with a capacity to hold up to 94 gallons
- Model HT80 is designed for boilers ranging from 61-80 HP with a capacity to hold up to 128 gallons
- Model HT100 is designed for boilers ranging from 81-100 HP with a capacity to hold up to 147 gallons
- Model HT150 is designed for boilers ranging from 101-150 HP with a capacity to hold up to 220 gallons
- Model HT200 is designed for boilers ranging from 151-200 HP with a capacity to hold up to 220 gallons
- Model HT250 is designed for boilers ranging from 201-250 HP with a capacity to hold up to 317 gallons
- Model HT300 is designed for boilers ranging from 251-300 HP with a capacity to hold up to 317 gallons
- Model HT350 is designed for boilers ranging from 301-350 HP with a capacity to hold up to 432 gallons
- Model HT400 is designed for boilers ranging from 351-400 HP with a capacity to hold up to 432 gallons
- Model HT500 is designed for boilers ranging from 401-500 HP with a capacity to hold up to 504 gallons
Vertical Feedwater and Condensate Return System
Vertical feedwater and condensate return systems are uniquely designed in a vertical, space-saving, compact orientation. These condensate return systems are available for boilers ranging from 1 HP up to 100 HP. Both the Fulton vertical and horizontal condensate return systems are offered in long-lasting, heavy gauge steel only. Vertical tanks have the exact components and assembly as the horizontal tank, including:
- Complete float assembly that can be easily removed without having to drain the tank
- A design that allows the tank to be serviced from the top
- Higher head pressure that leads to increased pump life under standard operation
- Vertical return systems can be ordered as a separate component or skid-mounted and piped to your boiler.
Vertical System Models and Dimensions
- Model VT10 is designed for boilers ranging from 4-12.5 HP with a capacity to hold up to 33 gallons
- Model VT20 is designed for boilers ranging from 13-21 HP with a capacity to hold up to 40 gallons
- Model VT30 is designed for boilers ranging from 22-30 HP with a capacity to hold up to 46 gallons
- Model VT50 is designed for boilers ranging from 31-50 HP with a capacity to hold up to 71 gallons
- Model VT60 is designed for boilers ranging from 51-60 HP with a capacity to hold up to 94 gallons
- Model VT80 is designed for boilers ranging from 61-80 HP with a capacity to hold up to 128 gallons
- Model VT100 is designed for boilers ranging from 81-100 HP with a capacity to hold up to 147 gallons
Contact ATI of New York for Fulton Feedwater and Condensate Return Systems
ATI of New York is the authorized manufacturer’s representative for Fulton. We offer their entire line up of cutting-edge equipment, including:
- Horizontal feedwater and condensate return systems
- Vertical Feedwater and condensate return systems
Contact ATI of New York today for Fulton feedwater and condensate return systems.